Horizontal fertilizer mixer common failure analysis and treatment measures
Bio organic fertilizer production lines are prone to equipment wear and tear or malfunctions after prolonged use or improper operation, and then introduce the common fault analysis and solutions of horizontal fertilizer mixers
1, the drive shaft wear deformation; 2, bearing damage; 3. The bearing seat or reducer fixing bolt is loose
Treatment measures 1, repair or replace the drive shaft 2, replace the bearing; 3. Tighten the bolt again.
Reducer oil temperature is too high fault analysis 1, drive shaft wear deformation; 2, bearing damage; 3. Too much ash accumulates in the box, and the resistance increases.
Treatment measures 1, repair or replace the drive shaft; 2, replace the bearing; 3. Rinse in time.
Failure analysis of insufficient water content 1, water pressure is not enough 2, nozzle blockage
Treatment measures 1, increase the water pressure 2, clean or replace
Shaft end disk ash fault analysis 1, spindle wear 2, packing wear
Treatment measures 1, repair or replace 2, replace the filler.