Horizontal fertilizer mixer common failure analysis and treatment measures

 Bio organic fertilizer production lines are prone to equipment wear and tear or malfunctions after prolonged use or improper operation, and then introduce the common fault analysis and solutions of horizontal fertilizer mixers

1, the drive shaft wear deformation; 2, bearing damage; 3. The bearing seat or reducer fixing bolt is loose

Treatment measures 1, repair or replace the drive shaft 2, replace the bearing; 3. Tighten the bolt again.

Reducer oil temperature is too high fault analysis 1, drive shaft wear deformation; 2, bearing damage; 3. Too much ash accumulates in the box, and the resistance increases.

Treatment measures 1, repair or replace the drive shaft; 2, replace the bearing; 3. Rinse in time.

Failure analysis of insufficient water content 1, water pressure is not enough 2, nozzle blockage

Treatment measures 1, increase the water pressure 2, clean or replace

Shaft end disk ash fault analysis 1, spindle wear 2, packing wear

Treatment measures 1, repair or replace 2, replace the filler.